Abatacept

Trade name

Orencia

Presentation and preparation

For IV administration:

Vial size
(powder volume)
Fluid to add
Volume to add
Resulting concentration
250 mg
(negligible)
Water for injections 10 mL  25 mg/mL

Reconstitute to 25 mg/mL using the silicone-free, latex-free syringe provided. Slowly add diluent towards the wall of the vial and gently rotate to wet the powder. Do not use vial if vacuum is not present. Swirl and gently rotate vial to dissolve. Do not shake. Once completely dissolved, vent the vial with a needle to dissipate any foam.

For SC administration:

Prefilled autoinjector, prefilled syringe:

125 mg/1 mL 

IV administration

Powder for reconstitution only:

Do not administer without further dilution.

Further dilute to 10 mg/mL or weaker and infuse over 30 or 60 minutes via a 0.2 to 1.2 micron low protein binding in-line filter. Gently invert the bag to mix, do not shake.

Use only the silicone-free, latex-free syringe provided. If a standard syringe containing silicone is used during preparation, do not administer and contact pharmacy.

Use an IV bag for administration.

Other routes of administration

IM: Not recommended.

SC: Suitable. Prefilled autoinjectors or syringes only: Refer to relevant local guideline or Patient/Caregiver Instructions for Use booklet.

Compatible IV fluids

Sodium chloride 0.9%

Additional information

Observe closely for anaphylactic reactions.

For IV use and first dose SC: Use only when facilities for cardiac monitoring and cardio-pulmonary resuscitation exist.

Refrigerate, do not freeze.

Solution should be clear, colourless to pale yellow.

Discard any unused vial contents.

Protect from light during storage.


Leave your feedback for Abatacept